In 2007, the idea arose to add a wind turbine to the photovoltaic system on the roof of the Lycée Technique d’Ettelbruck.

During the 2007/2008 academic year, two Year 6 pupils designed the system as part of their “Energy and Environment” course. The installation site was determined, a suitable wind turbine was chosen and a mast appropriate for the roof construction was specified.
IMG_2396

Technical data:

Wind turbine

The wine turbine is a device made by Braun Windturbinen and features the following technical data:

 

  Antaris 1.7kW
Rotor 3 GFK – rotor blades; Ø 3.50m; low-noise due to winglets; stall controlled
Generator gearless; brushless; 3-phase; permanent magnet rotor (NdFeB); 10-pole
Power transmission slip rings / cable
Voltage up to 500 VDC
Rated output 1700 W
Start-up speed 2.4m/s
Nominal speed 12m/s
Survival speed 55m/s
Storm protection Voltage monitoring; helicopter position
Weight 89kg

 

Mast

A tilt mast was chosen to allow any potential changes to be made to the installation. The mast was designed and constructed by metal manufacturer Thill in Asselborn.

Mast technical data

  • Mast made of tubular steel, Ø139.7 x 5.0mm – Quality S235
  • Mast head with flange Ø220 x 10.00 – identical to foot flange WKA
  • Mast foot with hinge, for folding with the help of a hoist or similar
  • 2 heavy-duty fastening brackets mounted to the building, with clamping screw and safety bolts featuring a padlock to prevent unauthorised unscrewing of the brackets
  • maximum wind resistance of the installation according to manufacturer specifications………………………………………………………………….. 40 kN
  • weight of installation, manufacturer specification………………….. 0.75 kN
  • maximum wind pressure to mast tube, derivation see appendix 08 ……………………………………………………………………… 858 kN/m2

 

Support reactions

Perpendicular to the hinge

Fv= 0.75 + 6.0 x 0.166 = 1.75 kN

Horizontal to the brackets

FH=(1.40×3.93+0.858×0.14×3.932 /2)/1.25= 5.14kN

Bending moment in tube at upper mount

Moment caused by wind

M=1.40×3.93 +0.858×0.14×3.932 /2 = 6.43kNm

Deflection

f1=1/3x140x393.03 /2.10/106 /480.5= 2.81cm f2=1/8×85.8×0.14×3.93×393.03/2.1/106 /480.5= 0.36cm f= 3.17 cm

Secondary moment caused by displacement M’=(0.75+1⁄2×6.0×0.166)x3.17×10-2 =0.04kNm

Bending stress in tube

σ= 1.50 x 6.50 x 103 / 68.80 = 142 N/mm2 (1.50 = dynamic coefficient)

Safety against the stress limit k= 240 / 142 = 1.69
IMG_2381

Electrical installation

The electricity generated is fed into the public grid via a grid inverter (Windy Boy 1100).
IMG_0951

(caption)

Meter cabinet, frequency converter and inverter

The electrical energy generated is reimbursed by the energy supply company.
Schaltplan

(diagram)

Generator mit 3 Phasen = Generator with 3 phases

Schaltschrank = control cabinet

Energiezähler = energy meter

Einspeisung ins Netz = feeding into the grid

Öffentliches Stromversorgung = public electricity supply